Top Deodorizer For Homes and Offices For Spacious Rooms For Factory Emissions

For Spacious Rooms

method

Phytoncide-Type Odor Control Systems (PE Series)

Deodor odor control systems efficiently emit phytoncide into the room to literally recreate the fresh wholesome air of a forest. They can be adjusted to optimally suit the odor intensity and other particular conditions of the room, always keeping the room environment in a grefreshing zone.h

Other features include:

Type XA Standard
Air volume fixed fan
Used in 60Hz areas.
50mm diameter ball valves used for air volume adjustment.
XB Large air volume
Air volume fixed fan
XB models handle over 50m of piping and over 50 air outlets.Used in 50Hz areas.
50mm diameter ball valves used for air volume adjustment.
Option 24-hr pre-setting timer
Cord with ground connector
Installation Methods Dedicated pipe laying
Integration with air-conditioning system
Integration with OA-processing system

Specifications: XA (standard typej

Model PE-104XA PE-106XA PE-108XA PE-110XA
Dimensions (mm) 475~453~306H 602~453~306H 729~453~306H 856~453~306H
Weight 22kg 26kg 30kg 36kg
Material SUS304, PVC (coupling section)
Power Supply 1, 100V, 46W(50Hz), 56W(60Hz)
Coverge Area Up to 480m2 Up to 720m2 Up to 960m2 Up to 1,200m2
Essential oil
Cartridges
Up to 4 Up to 6 Up to 8 Up to 10

Specifications: XB (large air volume type)

Model PE-104XA PE-106XA PE-108XA PE-110XA
Dimensions (mm) 525~453~306H 652~453~306H 779~453~306H 906~453~306H
Weight 25kg 29kg 33kg 39kg
Material SUS304, PVC (coupling section)
Power Supply 1, 100V, 111W(50Hz), 151W(60Hz)
Coverge Area Up to 480m2 Up to 720m2 Up to 960m2 Up to 1,200m2
Essential oil
Cartridges
Up to 4 Up to 6 Up to 8 Up to 10

Installation Methods

T.Dedicated Pipe Laying

An odor control unit is installed in the machinery room or inside the ceiling, or other such place. The pipes from the odor control units connect to outlets installed in the ceiling surface of each room. They can connect to fan coil units in the rooms if present.

Air Outlet Type `
Type A
Type a
Shape Wind Type Wind Type
Color Ivory white Ivory white
Material `ar `ar
Outside Diameter 115mm 70mm
Coverage Area Up to 40m2 Up to 20m2

Number of air outlets per room yExample: Healthcare facility for the elderlyz

Type A Outlet Type B outlet
Living Room (1 per 3-4 person room) Living Room i1per 1-2 Person roomj
Cafeteria
Lounge (1 per 30m2)
Laundry Room
Dressing Room
Single Room (1 for under 15m2)
Dirty Utility Room (1 per 10m2) Lavatory (1 per 2 toilets)
Hallway (1 per 10m)

U.Integration with Air-Conditioning System

An odor control unit integrated into an air-conditioning system will effectively emit phytoncide. It can be installed by a number of different ways depending on the type of air-conditioning system.

V.Integration with@OA-Processing@System

An odor control unit integrated into an OA-processing system will effectively emit phytoncide. It can be installed by a number of different ways depending on the type of OA-processing system.